AI Demos Research — the structured-intelligence platform. Every verdict on these pages opens to the execution behind it.
Graded 5 October 2026

Can Mistral AI process a document with mixed digital and scanned pages?

Mistral AI processed the mixed PDF and included the scanned page in the Markdown output instead of skipping it. The scanned page appears in document order as tables and prose: the worksheet header, checks and readings, calibration note, time on site, and received by details are all present. The signature stays as an image reference.

1 of 1 test case passed

Every test case in this scenario has a result.

Pass rate100%1 of 1 with a result
Coverage1 of 1test cases with a result
1PassDid everything it was expected to do.
0FailNo test case failed.
0Not gradableEvery result here could be graded.
0UntestedEvery test case in this scenario has a result.
The pass rate is a summary. The evidence is the test case below: what we sent, what we checked, what the tool returned, and the proof.

The test case

Each test case is judged on its own: Pass, Fail, Not gradable, or Untested. The scenario result above counts this row.

Mixed pages — scanned page not skippedPassEvidence
What we sent
InputDocument (PDF)
Three-page PDF with page 2 image-only and pages 1 and 3 containing extractable text.
Open the PDF ↗
What the tool returned
Proof 1Output file (Markdown)
Markdown output showing page 2 rendered as tables and note text in document order. From outside the graded run; shown for context, not graded.
Markdown105 lines
Kirkhollow Analytical Laboratories Ltd

Job KAL-ESR-4471

# Equipment service report

# ---**CLIENT**

Braithe Estuary Partnership  
Estuary House, Vardenne Quay  
Braithe BR3 4LN

|  Job reference | **KAL-ESR-4471**  |
| --- | --- |
|  Date of visit | **29 January 2026**  |
|  Engineer | **R. Tarbert**  |
|  Instrument | **Kestrel 400 turbidity analyser**  |
|  Location | **Vardenne Quay pumping station**  |
|  Service interval | **Twelve months**  |

## Reported fault

Intermittent baseline noise on channel 2, reported by the Partnership on 21 January. The analyser had been running without attention since the annual service in January 2025.

## Work carried out

The flow cell was removed, stripped and cleaned, and the pump tubing set replaced. The optical window was found to be lightly fouled on the inner face; it was cleaned rather than replaced, and should be inspected again at the next visit. The analyser was recalibrated against the two-point standards and left running on channel 2 for an hour before the site was handed back. The completed worksheet is bound in as page 2 of this report.

KAL-ESR-4471

Page 1 of 3

Kirkhollow Analytical Laboratories Ltd

FIELD SERVICE

# Service worksheet

|  Job reference | KAL-ESR-4471  |
| --- | --- |
|  Instrument serial | GK-2214-77  |
|  Engineer | R. Tarbert  |
|  Date | 29 January 2026  |

# CHECKS AND READINGS

|  Flow cell condition on arrival | Fouled, inner face  |
| --- | --- |
|  Flow cell pressure after service | 2.4 bar  |
|  Zero drift over 30 minutes | 0.003 mg/l  |
|  Span recovery against standard | 99.4 per cent  |
|  Lamp hours at service | 8,140  |
|  Result | Pass  |

# Calibration certificate SR-4471/2

Analyser left in service on channel 2. Optical window to be inspected at the next visit.

# TIME ON SITE

|  Arrived | 29 January 2026, 09:15  |
| --- | --- |
|  Left | 29 January 2026, 13:40  |
|  Chargeable time | 4 hours 25 minutes  |
|  Next service due | January 2027  |

# RECEIVED BY

|  Name | M. Cairney  |
| --- | --- |
|  Position | Duty operator, Vardenne Quay  |
|  Date | 29 January 2026  |

![img-0.jpeg](assets/img-0.jpeg)

Engineer's signature

Service worksheet · KAL-ESR-4471

Page 2 of 3

Kirkhollow Analytical Laboratories Ltd

Job KAL-ESR-4471

## Parts fitted

|  Part | Code | Quantity  |
| --- | --- | --- |
|  Pump tubing set | PT-114 | 1  |
|  Flow cell O-ring, 12 mm | OR-0912 | 2  |
|  Inlet filter, 40 micron | IF-4004 | 1  |

## Declaration

The work described in this report was carried out to the standard set out in the service agreement. The analyser was left in service and calibrated. The next annual service falls due in January 2027.

|  Engineer | **R. Tarbert**  |
| --- | --- |
|  Countersigned | **Dr A. J. Prosser**  |
|  Report issued | **2 February 2026**  |

KAL-ESR-4471

Page 3 of 3
Open the Markdown file ↗
Expected vs. Found
✓Expected: The scanned page’s text appears in the output like the digital pages, instead of being skipped.Found: The scanned page appears in full as Markdown tables and prose in document order; the signature remains an image reference.
Supporting proof
Proof 2Screenshot
Run metadata card showing the default OCR pipeline, the sent complete PDF, and a successful run.
Open original ↗
Why this result

The scanned page was checked in the Markdown output. It appears in document order as tables and prose matching the source values, rather than being skipped; the signature remains an image reference.

Also observed on this row

Heading level drift. The scanned page’s section labels are H1, while the matching digital-page sections are H2.

Bold is lost. The scanned page shows the job reference in plain text, while the digital page shows that same value in bold.

Repeated heading promotion. Each label/value block on the scanned page is promoted into headings in the same way.

Ungraded first page. The first page contains a mangled heading in the source, but that page is not part of the graded page.

Tested by Chandresh Bisht · evidence dated 10 September 2026

Configuration and setup

How this tool was set up for the run and what the test needed in place. Each row is a fact from the run's records; a fact the records do not hold is left out, not guessed.

Software that produced the output
Mistral AI
Build or version
mistral-ocr-latest (model id echoed by the API; dated version not exposed)
Plan or tier
Mistral La Plateforme (metered OCR endpoint)
Surface
API
Set up before the run
A digital PDF with one scanned, image-only page was converted to Markdown from the complete file in one pass, using the default OCR pipeline with no flag tuning.
Pipeline
Document AI default OCR pipeline, single pass, no flag tuning.
Tested
10 September 2026 · Chandresh Bisht

How this scenario is graded

How we decide Pass, Fail and Not gradable. The same rules apply to every tool tested on this scenario.

How results are decided

Each test case gets one result per tool: Pass, Fail or Not gradable. A test case we haven't run yet shows Untested. There are no partial results.

The rules
  • Pass: the tool did everything the test expected, and nothing it said contradicts the correct answer.
  • Fail: at least one expected behaviour clearly didn't happen; the row says which and quotes the tool.
  • Not gradable: our evidence couldn't settle the outcome (for example a record we needed is missing). It is never counted as a fail, and the row says what's missing.

Where this sits in the benchmark

This page is one cell of a larger study: one tool, one scenario. Only this benchmark's frame appears here.

History of this result

What has happened to this result since it was first published. Runs and grades are never overwritten: a retest or a re-grade publishes a new result and keeps the earlier one readable.

from the publication record
6 October 2026First publishedConverting a complex PDF into clean Markdown with a hosted API v1

Act on this result

Nothing filed here edits the run or the grade. A challenge opens a review, and a review can produce a new run or a re-grade — which becomes the current result and leaves this one in the history.

This matches what I see

You run the same kind of test against your own setup and get the same behaviour.

Agree →
This does not match

Yours behaves differently. Tell us what you got, with a screenshot if you have one.

Disagree →
Point out an issue

Something here is wrong — a reference value, a transcription, a grade.

Report an issue →
Request a retest

On a newer build, a larger dataset, or your own setup.

Request a retest →
We have fixed this

Tell us what changed and we schedule a rerun of the failing test case. The old result stays as history.

Vendor notice →
Filed against this evidenceNothing yet. Challenges, counter-evidence and fix notices appear here with their outcome, and stay on the page after they are resolved.
Cite this result
aidemos.com/benchmarks/pdf-to-markdown-apis/results/mistral-ai/a-document-mixing-digital-and-scanned-pages · 1 pass · 0 fail · coverage 1/1 · graded 2026-10-05

The same record is available as structured data through the AI Demos MCP server, with the counts, the coverage and every per-test-case reason carried as fields.

Verify the proof files

These files support this result. Open a file to inspect the original evidence.

Input · Document (PDF) ↗application/pdf · 356 KB
Proof 1 · Output file (Markdown) ↗text/markdown; charset=utf-8 · 3 KB
Proof 2 · Screenshot ↗image/png · 93 KB
File fingerprints (SHA-256)

A fingerprint identifies the exact file used for this result.

Input · Document (PDF)096951b8eaf09740a926620943c7eb9b076e80144d76e7a90fb7f77056b6ef83
Proof 1 · Output file (Markdown)c3c28912ed7ca6c182ea98e1c5dbe90f2b85cd96960b3bfa8d02fda1c5081bb9
Proof 2 · Screenshot23df9b66379125f7d61696f26e909b1ba30112b1e32dc8f30cac2419e0feae49